Below a list of all menu options that can be used in the SystemSetting function of the OPH-5000i is shown.
The settings depicted in bold are default values.
When [CD output without CD] is set, the value of the area corresponding to the CD is not output even if the CD does not exist in the read barcode.
(It is output only for Code 11.)
This list is updated regularly.
Please contact your local Opticon dealer if your application needs a setting that is not in the list to find out whether it is already implemented or not.

Barcode reader settings

The list of system settings is divided into the following sections:
SectionsDescription
B.1 Enabling a single readable code
B.2 Enabling of readable codes
B.3 Disabling of readable codes
B.4 Options for UPC-A
B.5 Options for UPC-E
B.6 Options for EAN-13 and EAN-8
B.7 Options for Code39
B.8 Options for Codabar(NW7)
B.9 Options for Code 2of5
B.10 Options for IATA
B.11 Options for MSI/Plessey
B.12 Options for Telepen
B.13 Options for UK/Plessey
B.14 Options for Code 93
B.15 Options for Code 11
B.16 Read mode options
B.17 Redundant reading
B.18 White space around barcode (= margin)
B.19 Options for Composite codes
B.20 Default setting
B.21 Options for default values

B.1 Enabling a single readable code

Menu optionDescription
A0
J1
J2
J3
J4
J5
J6
A2
JD
A3
J7
J8
RA
AB
JE
JL
A4
A7
A9
A1
A6
A5
BLB
J9
JJ
JK
D5H
D6C
DG2
D5R
D5M
DG7
D6O
BC3
BC4
D4R
BC1
D38
BC0
BC5
BF4
D4K
BC2
DJ1
DJ4
DJ7
DJA
DJD
All codes excl. add-on
UPC only
UPC+2 only
UPC+5 only
EAN only
EAN+2 only
EAN+5 only
Code 39 only
TripOptic/Code 39 only
Codabar only
Industrial 2 of 5 only
Interleaved 2 of 5 only
S-Code only
Matrix 2 of 5 only
Chinese Post Matrix 2 of 5 only
Korean Postal Authority only
IATA only
MSI/Plessey only
TELEPEN (Telepen numeric) only
UK/Plessey only
Code 128/EAN128 only
Code 93 only
Code 11 only
GS1 DataBar only
GS1 DataBar Limited only
GS1 DataBar Expanded only
Intelligent Mail Barcode only
POSTNET only
PLANET only
Japanese Postal only
Netherlands KIX Code only
UK Postal (Royal Mail) only
Australian Postal only
PDF417 only
Micro PDF417 only
Codablock-F only
QR Code only
Micro QR Code only
DataMatrix(ECC200) only
Aztec Code only
Aztec Runes only
Chinese Sensible Code only
Maxi Code only
Machine Readable Passports only
Machine Readable Visas-A only
Machine Readable Visas-B only
Official Travel Documents 1 only
Official Travel Documents 2 only

B.2 Enabling of readable codes

Menu optionDescription
A0
R1
R2
R3
R4
R5
R6
JU
JV
JW
JO
JP
JQ
B2
JZ
B3
R7
R8
R9
BB
JS
WH
B4
B5
B6
B7
B9
B1
BLC
BCI
JX
JY
DR
BCF
BCG
D5F
D6A
DG3
D5P
D5K
DG8
D6M
D4P
BCD
D2U
BCC
BCH
BF2
D4L
BCE
DJ2
DJ5
DJ8
DJB
DJE
BCM
BCN
All codes excl. add-on
Enable UPC
Enable UPC+2
Enable UPC+5
Enable EAN
Enable EAN+2
Enable EAN+5
Enable EAN13
Enable EAN13+2
Enable EAN13+5
Enable EAN8
Enable EAN8+2
Enable EAN8+5
Enable Code 39
Enable TriOptic/Code 39
Enable Codabar
Enable Industrial 2 of 5
Enable Interleaved 2 of 5
Enable S-Code
Enable Matrix 2 of 5
Enable Chinese Post Matrix 2 of 5
Enable Korean Postal Authority
Enable IATA
Enable Code 93
Enable Code 128/EAN128
Enable MSI/Plessey
Enable TELEPEN (Telepen numeric)
Enable UK/Plessey (with CD)
Enable Code 11
Enable RSS
Enable RSS-14
Enable RSS-limited
Enable RSS-expanded
Enable PDF417
Enable Micro PDF417
Enable Intelligent Mail Barcode
Enable POSTNET
Enable PLANET
Enable Japanese Postal
Enable Netherlands KIX Code
Enable UK Postal (Royal Mail)
Enable Australian Postal
Enable Codablock-F
Enable QR Code
Enable Micro QR Code
Enable DataMatrix(ECC200)
Enable Aztec Code
Enable Aztec Runes
Enable Chinese Sensible Code
Enable Maxi Code
Enable Machine Readable Passports
Enable Machine Readable Visas-A
Enable Machine Readable Visas-B
Enable Official Travel Documents 1
Enable Official Travel Documents 2
Enable all 1D codes
Enable all 2D codes

B.3 Disabling of readable codes

Menu optionDescription
B0
X4C
X4D
X4E
X4F
X4G
X4A
X4K
X4L
DDK
DDL
VB
VC
JT
WI
VH
VD
VE
VF
VG
VA
BLA
BCU
SJ
SK
SL
BCR
BCS
D5G
D6B
DG4
D5Q
D5L
DG9
D6N
D4Q
BCP
D2V
BCO
BCT
BF3
D4M
BCQ
DJ3
DJ6
DJ9
DJC
DJF
BCY
BCZ
Disable all
Disable UPC+2
Disable UPC+5
Disable EAN
Disable EAN+2
Disable EAN+5
Disable all UPC and EAN
Disable Industrial 2 of 5
Disable Interleaved 2 of 5
Disable S-Code
Disable Matrix 2 of 5
Disable Code 39
Disable Codabar
Disable Chinese Post Matrix 2 of 5
Disable Korean Postal Authority
Disable IATA
Disable Code 93
Disable Code 128/EAN128
Disable MSI/Plessey
Disable TELEPEN(Telepen numeric)
Disable UK/Plessey
Disable Code 11
Disable RSS
Disable RSS-14
Disable RSS Limited
Disable RSS Expanded
Disable PDF417
Disable MicroPDF417
Disable Intelligent Mail Barcode
Disable POSTNET
Disable PLANET
Disable Japanese Postal
Disable Netherlands KIX Code
Disable UK Postal (Royal Mail)
Disable Australian Postal
Disable Codablock-F
Disable QR Code
Disable Micro QR Code
Disable DataMatrix(ECC200)
Disable Aztec Code
Disable Aztec Runes
Disable Chinese Sensible Code
Disable Maxi Code
Disable Machine Readable Passports
Disable Machine Readable Visas-
Disable Machine Readable Visas-B
Disable Official Travel Documents 1
Disable Official Travel Documents 2
Disable all 1D codes
Disable all 2D codes

B.4 Options for UPC-A

Menu optionDescriptionDefault
E3 UPC-A, No leading zero, transmit CD
E5 UPC-A, No leading zero, not transmit CD
E2 UPC-A, Leading zero, transmit CD
E4 UPC-A, Leading zero,not transmit CD

B.5 Options for UPC-E

Menu optionDescriptionDefault
E7 UPC-E, No leading digit, transmit CD
E9 UPC-E, No leading digit, not transmit CD
E6 UPC-E, Leading digit, transmit CD
E8 UPC-E, Leading digit, not transmit CD

B.6 Options for EAN-13 and EAN-8

Menu optionDescriptionDefault
6J EAN−13 not transmit CD
6K EAN−13 transmit CD
6H EAN−8 not transmit CD
6I EAN−8 transmit CD

B.7 Options for Code39

Menu optionDescriptionDefault
C1 Not check CD
C0 Check CD
D8 Not transmit CD
D9 Transmit CD
D1 Not transmit ST/SP
D0 Transmit ST/SP
D5 Normal Code 39
D4 Full ASCII Code 39
D7 It. Pharmaceutical if possible
 By default (D5), both Full ASCII Code and It. Pharmaceutical are read as standard Code 39.
 If set D4, Normal Code 39 will read as Full ASCII Code 39.
 If D7 is set and it is determined to be It. Pharmaceutical, it will be read as It. Pharmaceutical.

B.8 Options for Codabar(NW7)

Menu optionDescriptionDefault
H7 Not check CD
H6 Check CD
H9 Not transmit CD
H8 Transmit CD
F0 Not transmit ST/SP
F3 ST/SP:
ABCD/ABCD

F4 ST/SP:
abcd/abcd

F1 ST/SP:
ABCD/TN*E

F2 ST/SP:
abcd/tn*e

DB2 Arbitrarily specify the minimum number
of characters allowed.(default 2 characters)
For numbers, specify Q0 to Q9 followed
by the menu code in 4 digits.
5 character setting example:[DB2Q0Q0Q0Q5

HA Enable only Codabar normal mode
H3 Enable Codabar, ABC and CX

B.9 Options for Code 2of5

Menu optionDescriptionDefault
E1 Not transmit CD
E0 Transmit CD
G0 Not check CD
G1 Check CD

B.10 Options for IATA

Menu optionDescriptionDefault
4H Not check CD
4I Check FC and SN only
4J Check CPN, FC and SN
4K Check CPN, AC, FC and SN
4M Not transmit CD
4L Transmit CD

B.11 Options for MSI/Plessey

Menu optionDescriptionDefault
4A Not check CD
4B Check 1 CD = MOD 10
4C Check 2 CD's = MOD 10/MOD 10
4D Check 2 CD's = MOD 10/MOD 11
4R Check 2 CD's = MOD11/MOD10
4S Check 2 CD's = MOD11/MOD11
4G Not transmit CD
4E Transmit CD1
4F Transmit CD1 and CD2

B.12 Options for Telepen

Menu optionDescriptionDefault
D2 Numeric mode
D3 ASCII moe

B.13 Options for UK/Plessey

Menu optionDescriptionDefault
4O Not transmit CD's
4N Transmit CD's

B.14 Options for Code93

Menu optionDescriptionDefault
9Q Not check CD
AC Check CD

B.15 Options for Code11

Menu optionDescriptionDefault
BLF Not check CD
BLG Check 1 CD
BLH Check 2 CDs
BLI Check auto 1 or 2 CDs
BLJ Not transmit CD(s)
BLK Transmit CD(s)

B.16 Read mode options

Menu optionDescriptionDefault
XA Add-on wait mode disabled
XB Add-on wait mode 0.25 sec
XC Add-on wait mode 0.50 sec
XD Add-on wait mode 0.75 sec

B.17 Redundant reading

Menu optionDescriptionDefault
X0 Read 1 time , redundancy = 0
X1 Read 2 time , redundancy = 1
X2 Read 3 time , redundancy = 2
X3 Read 4 time , redundancy = 3

B.18 White space around barcode (= margin)

Menu optionDescriptionDefault
YN No margin check
YO Margin check 1/7 nominal
YP Margin check 2/7 nominal
YQ Margin check 3/7 nominal
YR Margin check 4/7 nominal
YS Margin check 5/7 nominal
YT Margin check 6/7 nominal
YU Margin check normal

B.19 Options for Composite codes

Menu optionDescriptionDefault
BHE Enable Composite on GS1 Databar
BHF Disable Composite on GS1 Databar
D1V Enable Composite on UPC/EAN
D1W Disable Composite on UPC/EAN
 ※ It is necessary to allow the reading settings of the two types of barcodes to be combined.

B.20 Default setting

Menu optionDescription
U2 Initialize all settings

B.21 Options for default values

Type of barcodeDefault Type of barcodeDefault
UPC GS1 DataBar
EAN13 GS1 DataBar Limited
EAN13+2
GS1 DataBar Expanded
EAN13+5
PDF417
EAN8 MicroPDF417
EAN8+2
Intelligent Mail Barcode
EAN8+5
POSTNET
Code 39 PLANET
TriOptic/Code 39 Japanese Postal
Codabar Netherlands KIX Code
Industrial 2 of 5 UK Postal (Royal Mail)
Interleaved 2 of 5 Australian Postal
S-Code
Codablock-F
Matrix 2 of 5
QR Code
Chinese Post Matrix 2 of 5
Micro QR Code
Korean Postal Authority
DataMatrix(ECC200)
IATA Aztec Code
Code 93 Aztec Runes
Code 128/EAN128 Chinese Sensible Code
MSI/Plessey
Maxi Code
TELEPEN (Telepen numeric)
Machine Readable Passports
UK/Plessey (with CD)
Code 11
Machine Readable Visas-A
Machine Readable Visas-B
Official Travel Documents 1
Official Travel Documents 2

Last updated: 2020/10/02